MC74VHC126
AC ELECTRICAL CHARACTERISTICS (Input tr = tf = 3.0 ns)
Symbol
Parameter
tPLH,
tPHL
Maximum Propagation
Delay,
A to Y
tPZL,
tPZH
Maximum Output
Enable TIme,
OE to Y
tPLZ,
tPHZ
Maximum Output
Disable Time,
OE to Y
tOSLH, Output--to--Output Skew
tOSHL
Cin Maximum Input
Capacitance
Cout Maximum Three--State
Output Capacitance
(Output in High
Impedance State)
Test Conditions
VCC = 3.3 ± 0.3 V
VCC = 5.0 ± 0.5 V
VCC = 3.3 ± 0.3 V
RL = 1.0 kΩ
VCC = 5.0 ± 0.5 V
RL = 1.0 kΩ
VCC = 3.3 ± 0.3 V
RL = 1.0 kΩ
VCC = 5.0 ± 0.5 V
RL = 1.0 kΩ
VCC = 3.3 ± 0.3 V
(Note 3)
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 15 pF
CL = 50 pF
CL = 50 pF
CL = 50 pF
CL = 50 pF
VCC = 5.0 ± 0.5 V CL = 50 pF
(Note 3)
TA = 25°C
Min Typ Max
5.6 8.0
8.1 11.5
3.8 5.5
5.3 7.5
5.4 8.0
7.9 11.5
3.6 5.1
5.1 7.1
9.5 13.2
6.1 8.8
1.5
1.0
4.0 10
6.0
TA = ≤ 85°C TA = ≤ 125°C
Min Max Min Max Unit
1.0 9.5 1.0 12.0 ns
1.0 13.0 1.0 15.0
1.0 6.5 1.0 8.5
1.0 8.5 1.0 10.5
1.0 9.5 1.0 11.5 ns
1.0 13.0 1.0 15.0
1.0 6.0 1.0 7.5
1.0 8.0 1.0 9.5
1.0 15.0 1.0 18.0 ns
1.0 10.0 1.0 12.0
1.5
1.5 ns
1.0
1.0
10
10 pF
pF
Typical @ 25°C, VCC = 5.0V
CPD Power Dissipation Capacitance (Note 4)
15
pF
3. Parameter guaranteed by design. tOSLH = |tPLHm -- tPLHn|, tOSHL = |tPHLm -- tPHLn|.
4. CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load.
Average operating current can be obtained by the equation: ICC(OPR) = CPD ¯ VCC ¯ fin + ICC/4 (per buffer). CPD is used to determine the
no--load dynamic power consumption; PD = CPD ¯ VCC2 ¯ fin + ICC ¯ VCC.
NOISE CHARACTERISTICS (Input tr = tf = 3.0 ns, CL = 50 pF, VCC = 5.0 V)
Symbol
VOLP
VOLV
VIHD
VILD
Characteristic
Quiet Output Maximum Dynamic VOL
Quiet Output Minimum Dynamic VOL
Minimum High Level Dynamic Input Voltage
Maximum Low Level Dynamic Input Voltage
TA = 25°C
Typ
Max
Unit
0.3
0.8
V
-- 0.3
-- 0.8
V
3.5
V
1.5
V
http://onsemi.com
5