MITSUBISHI ELECTRIC
INTEGRATED POWER FUNCTIONS
4th generation (planar) IGBT inverter bridge for 3 phase DC-to-AC power conversion.
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS
• For upper-leg IGBTS :Drive circuit, High voltage isolated high-speed level shifting, Control circuit under-voltage (UV) protection.
Note : Bootstrap supply scheme can be applied.
• For lower-leg IGBTS : Drive circuit, Control circuit under-voltage protection (UV), Short circuit protection (SC).
• Fault signaling : Corresponding to a SC fault (Low-side IGBT) or a UV fault (Low-side supply).
• Input interface : 5V line CMOS/TTL compatible, Schmitt Trigger receiver circuit.
APPLICATION
AC100V~200V three-phase inverter drive for small power motor control.