Panasonic Corporation
FEATURES
• Compact, high-capacity, and
resistant to inductive loads
It can control an inductive load with
inrush current of 80 A and steady
state current of 20 A.
• Excellent contact welding resistance
High contact pressure, a forced opening
mechanism, and a forced wiping
mechanism realizes an excellent contact
welding resistance.
• High breakdown voltage and surge
resistant relay
More than 6.4 mm .252 inch maintained
for the insulation distance between
contacts and coil, and the breakdown
voltage between contacts and coil is
5,000 V for 1 minute. In addition, the
surge resistance between contacts and
coil is greater than 10,000 V.
• Resistant to external force
An absorber mechanism is used on the
load terminals, giving a large
improvement in characteristics variations
caused by the external force during
FASTON placement/removal.
• Flux resistance mechanism
The terminal area is plugged with resin to
prevent flux seepage during PCB
mounting. (TMP type)
• Conforms to the various safety
standards
UL, CSA, VDE available
• The line up can support economical
mounting methods.
The relay are equipped with a drive
terminal (coil terminal) on one side for
PCBs, and a load terminal (tab terminal
#250) on the reverse side. The line up
includes the TM type which can be
attached directly to the PCB composing a
drive circuit, and the TMP type which
supports economical wiring. The TMP
type can also be directly attached, and a
high capacity load can be wired to the tab
terminal.
TYPICAL APPLICATIONS
• Compressor and heater control in
air conditioners
• Power control in hot air type heaters
• Magnetron control in microwave
ovens
• Lamp and motor control in
OA equipment such as copiers and
facsimiles.