LTC7000/LTC7000-1
TYPICAL APPLICATIONS
Protected Redundant Supply Switchover with Shoot Through Protection
MAIN POWER
7V TO 135V
2×
0.003Ω BSC320N20NS3G
LOAD
2×
BSC320N20NS3G 0.0015Ω
10µF
100Ω
100Ω
0.1µF
200k
6.98k
SNS+
VIN
RUN
SNS– TGDN
TGUP
TS
BST
LTC7000
INP
FAULT
VCCUV
IMON
ISET
GND
VCC
TIMER
OVLO
0.1µF
100k 1µF
1nF
10µF
100Ω
10Ω 10Ω
0.1µF
1nF 4.99k
0.1µF
TGUP
TS
BST
TGDN SNS–
SNS+
VIN
RUN
FAULT LTC7000
1µF
VCC
INP
TIMER
OVLO
GND
VCCUV
IMON
ISET
7000 TA02
VBACKUP
7V TO 135V
10µF
100Ω
0.1µF
NOTE: THE BACKUP PATH
WILL LATCH-OFF WITH AN
OVERCURRENT FAULT.
VLOAD vs Main Power Voltage
80 VBACKUP = 60V
70
60
50
40
30
0 10 20 30 40 50 60 70 80
MAIN POWER (V)
7000 TA02b
VMAIN Falling Through 33V
VTG–TS
MAIN
10V/DIV
RLOAD = 50Ω
VTG–TS
BACKUP
10V/DIV
VLOAD
20V/DIV
40µs/DIV
7000 TA02c
VMAIN Rising Through 36V
VTG–TS
MAIN
10V/DIV
RLOAD = 50Ω
VTG–TS
BACKUP
10V/DIV
VLOAD
20V/DIV
10µs/DIV
7000 TA02d
For more information www.analog.com
Rev. E
23