6.2. Channel Setting
SNAD02C
8-CHANNEL 10-BIT ADC
START
CLK
Channel Setting
HiZ
DIO
CM2 CM1 CM0 CH[7] CH[6] CH[5] CH[4] CH[3] CH[2] CH[1] CH[0] X
X
X
X
X
Port Input
Figure-4 The timing diagram of channel attribute/wakeup setting
(1) Command 001: channel attribute setting.
(2) Command 010: wakeup function setting.
In attribute setting, “1” means analog and “0” means digital. In wakeup setting, “1” means enable
and “0” means disable. After all of the channels are set, the DIO port remains input mode and all
the following data are ignored.
6.3. Control Register Setting
START
CLK
Control Register Setting
DIO
HiZ
CM2
CM
1
CM0
PH
PL
RF
MB
X
X
X
XX
X
XXX
Port Input
Figure-5 The timing diagram of control registers setting
(1) Command ID: (011)
(2) 4-bit data behind command ID are loaded into control registers with the sequence of PH, PL,
RF and MB.
(3) The function of each control registers are as Table-3.
Version: 1.3
7
July 31, 2003