NJU7700/01
s NJU7701
s ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Input Voltage
Output Voltage
Output Current
Power Dissipation
Operating Temperature
VDD
VOUT
IOUT
PD
Topr
Storage Temperature
Tstg
(Ta=25°C)
RATINGS
UNIT
+10
V
VSS-0.3 ∼ VDD+0.3
V
50
mA
200
mW
−40 ∼ +85
°C
−40 ∼ +125
°C
s ELECTRICAL CHARACTERISTICS (Ta=25°C)
PARAMETER SYMBOL
TEST CONDITION
MIN. TYP. MAX. UNIT
Detection Voltage
Hysteresis Voltage
Quiescent Current
Output Current
Detection Voltage
Temperature
Coefficient
Operating Voltage
(*note 1)
VDET
VHYS
ISS
IOUT
VDD=VDET+1V
Nch,VDS=0.5V
Pch,VDS=0.5V
∆ VDET /∆Ta Ta=0 ∼ +85°C
VDD
RL=100kΩ
VDET=1.3V∼1.7V Version
VDET=1.8V∼6.0V Version
VDD=1.2V
VDD=2.4V (≥2.7V Version)
VDD=4.8V (≤3.9V Version)
VDD=6.0V
(4.0V∼5.6V Version)
VDD=8.4V (≥5.7V Version)
-1.0% − +1.0% V
VDET VDET VDET
×0.03 ×0.05 ×0.08
V
−
−
0.5
0.8
1.0
1.6
uA
0.75 2.0
−
4.5 7.0
−
2.0 3.5
−
mA
2.5 4.0
−
3.0 5.0
−
− ±100 − ppm/°C
0.8 −
9
V
*note 1 : The minimum Operating Voltage(VOPL) indicates the same value of the output voltage(VOUT) on
condition that VOUT becomes 10% or less of the input voltage(VDD).
Ver.2003-03-10
-3 -