datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

LA55-TP/SP27 Ver la hoja de datos (PDF) - LEM Industrial

Número de pieza
componentes Descripción
fabricante
LA55-TP/SP27
LEM
LEM Industrial 
LA55-TP/SP27 Datasheet PDF : 3 Pages
1 2 3
Current Transducer LA 55-TP/SP27
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 50 A
16086
Electrical data
IPN
Primary nominal current rms
IPM Primary current, measuring range
RM Measuring resistance
with ± 12 V
@ ± 50 A max
@ ± 100 A max
with ± 15 V
@ ± 50 A max
@ ± 100 A max
ISN
Secondary nominal current rms
KN Conversion ratio
VC
Supply voltage (± 5 %)
IC
Current consumption
Accuracy - Dynamic performance data
50
A
0 .. ± 100
A
R R M min
M max
0 210
0
30
30 320
30 90
25
mA
1 : 2000
± 12 .. 15
V
10 (@ ± 15 V)+ IS mA
X
Accuracy @ IPN , TA = 25°C @ ± 15 V (± 5 %)
@ ± 12 .. 15 V (± 5 %)
ε
L
Linearity error
± 0.65
± 0.90
< 0.15
Typ Max
IO
Offset current @ IP = 0, TA = 25°C
IOM
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 x IPN
IOT
Temperature variation of IO
- 25°C .. + 85°C ± 0.1
- 40°C .. - 25°C ± 0.2
± 0.1
± 0.2
± 0.3
± 0.5
tra
tr
di/dt
Reaction time to 10 % of IPN step
Response time 2) to 90 % of IPN step
di/dt accurately followed
< 500
< 1
> 200
BW Frequency bandwidth (- 1 dB) DC .. 200
%
%
%
mA
mA
mA
mA
ns
µs
A/µs
kHz
General data
TA
Ambient operating temperature - 40 .. + 85
°C
TS
Ambient storage temperature - 50 .. + 90
°C
RS Secondary coil resistance @ TA = 85°C 140
m
Mass 35
g
Standards EN 50155: 1995
Features
Closed loop (compensated)
current transducer using the Hall
effect
Mounted on printed circuit board
Insulated plastic case recognized
according to UL 94-V0.
Special features
IPM = 0 .. ± 100 A
● KN = 1 : 2000
● Vd = 3.6 kV
● TA = - 40°C .. + 85°C
Potted.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
Single or three phases inverter
Propulsion and braking chopper
Propulsion converter
Auxiliart converter
Battery charger.
Application domain
Traction.
Notes: 1) Result of the coercive field of the magnetic circuit
2) With a di/dt of 100 A/µs.
090616/4