Philips Semiconductors
CATV amplifier modules
Product specification
BGY84A; BGY85A
CHARACTERISTICS
Table 1 Bandwidth 40 to 450 MHz; Tmb = 30 °C; ZS = ZL = 75 Ω
SYMBOL
Gp
SL
FL
S11
S22
CTB
Xmod
d2
Vo
F
Itot
PARAMETER
power gain
slope cable equivalent
flatness of frequency response
input return losses
output return losses
composite triple beat
BGY84A
BGY85A
cross modulation
BGY84A
BGY85A
second order distortion
output voltage
BGY84A
BGY85A
noise figure
BGY84A
BGY85A
total current consumption
BGY84A
BGY85A
CONDITIONS
MIN.
f = 50 MHz
18
f = 450 MHz
18.7
f = 40 to 450 MHz
0.3
f = 40 to 450 MHz
−
f = 40 to 80 MHz
20
f = 80 to 160 MHz
19
f = 160 to 450 MHz
18
f = 40 to 80 MHz
20
f = 80 to 160 MHz
19
f = 160 to 450 MHz
18
60 channels flat; Vo = 46 dBmV;
measured at 445.25 MHz
−
−
60 channels flat; Vo = 46 dBmV;
measured at 55.25 MHz
−
−
note 1
−
dim = −60 dB; note 2
60
62.5
f = 40 to 450 MHz
−
−
DC value; VB = +24 V; note 3
−
−
TYP.
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
180
220
MAX. UNIT
18.8 dB
20.2 dB
1.5 dB
±0.2 dB
−
dB
−
dB
−
dB
−
dB
−
dB
−
dB
−55 dB
−59 dB
−58 dB
−61 dB
−72 dB
−
dBmV
−
dBmV
6.5 dB
7
dB
200 mA
240 mA
Notes
1. fp = 55.25 MHz; Vp = 46 dBmV;
fq = 343.25 MHz; Vq = 46 dBmV;
measured at fp + fq = 398.5 MHz.
2. Measured according to DIN45004B;
fp = 440.25 MHz; Vp = Vo;
fq = 447.25 MHz; Vq = Vo −6 dB;
fr = 449.25 MHz; Vr = Vo −6 dB;
measured at fp + fq − fr = 438.25 MHz.
3. The modules normally operate at VB = +24 V, but are able to withstand supply transients up to +30 V.
1997 Apr 10
3