DC Electrical Characteristics for ACT
Symbol
Parameter
VCC
TA = +25°C
TA = −55°C to +125°C TA =−40°C to +85°C
Units
Conditions
(V)
Typ
Guaranteed Limits
VIH
Minimum HIGH Level
4.5
1.5
2.0
2.0
Input Voltage
5.5
1.5
2.0
2.0
VIL
Maximum LOW Level
4.5
1.5
0.8
0.8
Input Voltage
5.5
1.5
0.8
0.8
VOH
Minimum HIGH Level
4.5
4.49
4.4
4.4
Output Voltage
5.5
5.49
5.4
5.4
2.0
V VOUT = 0.1V
2.0
or VCC − 0.1V
0.8
V VOUT = 0.1V
0.8
or VCC − 0.1V
4.4
5.4
V IOUT = −50 µA
4.5
3.86
3.70
5.5
4.86
4.70
VOL
Maximum LOW Level
4.5
0.001
0.1
0.1
Output Voltage
5.5
0.001
0.1
0.1
3.76
4.76
0.1
0.1
IOH = 12
V IOH = 24 mA
IOH = 24 mA (Note 5)
V IOUT = 50 µA
4.5
5.5
IIN
Maximum Input
5.5
Leakage Current
0.36
0.50
0.36
0.50
±0.1
±1.0
0.44
0.44
±1.0
IOL = 12 mA
V IOL = 24 mA
IOL = 24 mA (Note 5)
µA VI = VCC, GND
IOZ
Maximum 3-STATE
5.5
Current
±0.25
±5.0
ICCT
Maximum
5.5
0.6
1.6
ICC/Input
IOLD
Minimum Dynamic
5.5
50
IOHD
Output Current (Note 6)
5.5
−50
ICC
Maximum Quiescent
5.5
Supply Current
4.0
80.0
±2.5
1.5
75
−75
40.0
µA VI = VIL, VIH
VO = VCC, GND
mA VI = VCC − 2.1V
mA VOLD = 1.65V Max
mA VOHD = 3.85V Min
µA VIN = VCC
or GND
Note 5: All outputs loaded; thresholds on input associated with output under test.
Note 6: Maximum test duration 2.0 ms, one output loaded at a time.
3