Si7013-A10
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter
Symbol Test Condition
Min
Typ
Power Supply
VDD
1.9
Operating Temperature
TA
I and Y grade
–40
Operating Temperature
TA
G grade
–40
Max
Unit
3.6
V
+125
°C
+85
°C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ
Max Unit
Input Voltage High
VIH
Input Voltage Low
VIL
AD0, SCL, SDA, VSNS pins
AD0, SCL, SDA, VSNS pins
0.7xVDD
V
0.3xVDD V
Input Voltage Range VIN SCL, SDA, VSNS pins with respect to
0.0
GND
VDD
V
Input Leakage
IIL
SCL, SDA pins; VIN = GND
VSNS pin (200K nominal pull up);
Vin = GND
5xVDD
1
μA
μA
Output Voltage Low VOL SDA pin; IOL = 2.5 mA; VDD = 3.3 V
0.6
V
SDA pin; IOL = 1.2 mA;
VDD = 1.9 V
0.4
V
Output Voltage High VOH VOUT pin, IOH = –0.5 mA, VDD = 2.0 V VDD – 0.2
VOUT pin, IOH = –10 μA
VDD– 0.1
VOUT pin, IOH = –1.7 mA, VDD = 3.0 V VDD – 0.4
V
V
V
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
2.
be
No
tcCoOnNvVe(rRsHio)n+otrCIO2CNVt(rTan).saction
in
progress.
Typical
values
measured
at
25
°C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, Read Firmware Version, Read/Write
Thermistor Coefficients and Measure Analog Voltage or Thermistor Temperature. Duration is <50 μs for all commands
except Measure Analog Voltage or Thermistor Temperature, which has <150 μs duration when Thermistor Correction is
enabled.
5. IDD after a user register write. Initiating any other subsequent I2C transaction on the same bus (such as a user register
read, starting an RH measurement, or traffic directed at other I2C devices) will transition the device to standby mode.
6. Additional current consumption when HTRE bit enabled. See Section “5.6. Heater” for more information.
4
Rev. 1.0

Share Link: 