CY7C64215
DC POR and LVD Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and 0°C < TA < 70°C, or 3.0V to 3.6V and 0°C < TA < 70°C, respectively. Typical parameters apply to 5V or 3.3V at 25°C and are for
design guidance only.
Note The bits PORLEV and VM in the table below refer to bits in the VLT_CR register. See the PSoC Mixed-Signal Array Technical
Reference Manual for more information on the VLT_CR register.
Table 16. DC POR and LVD Specifications
Parameter
Description
VPPOR0R
VPPOR1R
VPPOR2R
VPPOR0
VPPOR1
VPPOR2
VPH0
VPH1
VPH2
VLVD0
VLVD1
VLVD2
VLVD3
VLVD4
VLVD5
VLVD6
VLVD7
Vdd Value for PPOR Trip (positive ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
Vdd Value for PPOR Trip (negative ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
PPOR Hysteresis
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
Vdd Value for LVD Trip
VM[2:0] = 000b
VM[2:0] = 001b
VM[2:0] = 010b
VM[2:0] = 011b
VM[2:0] = 100b
VM[2:0] = 101b
VM[2:0] = 110b
VM[2:0] = 111b
Min
–
–
–
–
–
2.86
2.96
3.07
3.92
4.39
4.55
4.63
4.72
Typ. Max Unit
2.91
V
4.39
–
V
4.55
V
2.82
V
4.39
–
V
4.55
V
92
–
mV
0
–
mV
0
–
mV
2.92 2.98[4] V
3.02 3.08
V
3.13 3.20
V
4.00 4.08
V
4.48 4.57
V
4.64 4.74[5] V
4.73 4.82
V
4.81 4.91
V
Notes
Notes
4. Always greater than 50 mV above PPOR (PORLEV = 00) for falling supply
5. Always greater than 50 mV above PPOR (PORLEV = 10) for falling supply
Document 38-08036 Rev. *B
Page 19 of 30