DC and Operating Characteristics (1-2)
TA = 0°C to 70°C, VCC = 5 V ± 10%, VSS = 0 V, unless otherwise specified.
Symbol
Parameter
Access
V53C16258H
Time Min. Typ. Max. Unit
Test Conditions
Notes
ILI
Input Leakage Current
(any input pin)
–10
10
µA VSS ≤ VIN ≤ VCC
ILO
Output Leakage Current
(for High-Z State)
ICC1
VCC Supply Current,
Operating
–10
25
30
10
µA VSS≤ VOUT ≤ VCC
RAS, CAS at VIH
260
mA tRC = tRC (min.)
1, 2
200
35
190
40
180
45
100
50
90
ICC2
VCC Supply Current,
TTL Standby
ICC3
VCC Supply Current,
25
RAS-Only Refresh
30
2
mA RAS, CAS at VIH
other inputs ≥ VSS
260
mA tRC = tRC (min.)
2
200
35
190
40
180
45
100
50
90
ICC4
VCC Supply Current,
25
EDO Page Mode Operation
30
200
mA Minimum Cycle
1, 2
140
35
130
40
120
45
90
50
80
ICC5
VCC Supply Current,
Standby, Output Enabled
other inputs ≥ VSS
ICC6
VCC Supply Current,
CMOS Standby
ICC7
Self Refresh Current
VCC
Supply Voltage
VIL
Input Low Voltage
VIH
Input High Voltage
VOL
Output Low Voltage
VOH
Output High Voltage
2
mA RAS = VIH, CAS = VIL
1
1
mA RAS ≥ VCC – 0.2 V,
CAS ≥ VCC– 0.2 V,
All other inputs ≥ VSS
400
µA CBR Cycle with tRAS ≥ tRASS
(Min.) and CAS = VIL;
WE = VCC–0.2V; A0–A8 and
DIN = VCC–0.2V
4.5
5.0
5.5
V
–1
0.8
V
3
2.4
VCC + 1 V
3
0.4
V IOL = 2 mA
2.4
V IOH = –2 mA
V53C16258H Rev. 3.8 November 1999