S5L9291X
DIGITAL SIGNAL PROCESSOR
Soft ATTN On Sequence
In Soft Attn Command, Fade_in or Fade_out functions can be operated within 23.2ms
Fade Out :when $5D,1111_1110 Command is entered, Sound is fade out within 23.2ms
Fade In: When $5D,1111_1110 Command is entered, that is , from the start position of the music in Fade Out,
when $5D 0000_0010 Command is entered, sound is fade in within 23.2ms.
Soft ATTN On Sequence
Soft ATTN On
Sequence
Soft ATTN On
$5D,0000_0010
Fade Out ?
No
Yes
Soft ATTN On
$5D,1111_1110
Fade Out within
23.3ms
Forbidden
No
Fade In
Yes
No
Fade Out State?
Yes
Soft ATTN On
$5D,0000_0010
Fade In within 23.2ms
Attenuation Level
Setting
$5D,xxxx_xx10
84