Advance Information
Addresses
CE#
OE#
WE#
Data
RY/BY#
Program Command Sequence (last two cycles)
tWC
555h
tAS
PA
tAH
tCH
Read Status Data (last two cycles)
PA
PA
tWP
tCS
tWPH
tDS
tDH
A0h
tPOLL
PD
tBUSY
tWHWH1
Status DOUT
tRB
VCC
tVCS
Notes:
1. PA = program address, PD = program data, DOUT is the true data at the program address.
2. Illustration shows device in word mode.
Figure 16. Program Operation Timings
VHHHH
ACC
VIILL or VIIHH
tVVHHHH
Figure 17. Accelerated Program Timing Diagram
tVVHHHH
VIILL or VIIHH
April 22, 2005 S29GL-A_00_A3
S29GL-A MirrorBit™ Flash Family
73