ABSOLUTE MAXIMUM RATINGS
Parameter
Power Supply Voltage
Input Voltage
Storage Temperature
Output Short Current
Power Dissipation
Symbol
VDD
VI
Tstg
ISHT
PD
Condition
Ta = 25°C
With respect to GND
—
Short to VDD or GND
—
ML7005
Rating
Unit
–0.3 to +7.0
V
–0.3 to VDD + 0.3
–55 to +150
°C
35
mA
100
mW
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Condition
Power supply voltage
VDD
—
Operating Temperature Range
TOP
—
Input Clock Frequency Deviation fCLK An external clock is applied to
Input Clock duty
DUTY X1
X1, X2 Load Capacitance
C1, C2
—
SG Bypass Capacitance
C3 SG - GND
VDD Bypass Capacitance
C4 VDD - GND
Digital Input Rise Time
Digital Input Fall Time
C5
TIR PD, READ, CS,
TIF ALE, WR, D3 to D0
Digital Ouput Load Capacitance CDL1 FCDO, CPDO, D3 to D0
CDL2 CLKO
Frequency Deviation
— +25°C ±5°C
Temperature Characteristics — –30°C to +85°C
Equivalent Series Resistance —
—
Load Capacitance
—
—
Min. Typ. Max. Unit
2.7 3.6 5.5
V
–30 — +85 °C
–0.1 — +0.1 %
40
—
60
%
18
20
22
pF
1
—
—
10
—
—
mF
0.1
—
—
—
—
50
ns
—
—
50
—
—
40
pF
—
—
20
–100 — +100
ppm
–100 — +100
—
—
90
W
—
16
—
pF