Absolute maximum ratings and operating conditions
LM2902H
Table 2. Operating conditions
Symbol
Parameter
Value
Unit
VCC
Supply voltage (VCC+ - VCC-)
3 to 30
V
Toper Operating free-air temperature range
-40 to +150
°C
Input common-mode voltage range (VCC = 30 V)(1)
Vicm
Tamb = 25° C
0 to VCC+ -1.5
V
Tmin ≤ Tamb ≤ Tmax
0 to VCC+ -2
1. The input common-mode voltage of either input signal voltage should not be allowed to go negative by
more than 0.3 V. The upper end of the common-mode voltage range is VCC+ –1.5 V, but either or both
inputs can go to +32 V without damage.
4/13
Doc ID 16486 Rev 1