FLC10 Ver la hoja de datos (PDF) - STMicroelectronics

Número de pieza
componentes Descripción
fabricante
FLC10
ST-Microelectronics
STMicroelectronics 
FLC10 Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
Characteristics
FLC10
The applications of the lighter using the capacitance discharge topology operate in 2
phases:
Phase 1
The energy coming from the mains is stored into the capacitor C. For that, the AC voltage is
rectified by the diode Ds.
Phase 2
At the end of the phase 1, the voltage across the capacitor C reaches the avalanche
threshold of the zener. Then a current flows through the gate of the thyristor Th which fires.
– The firing of the thyristor causes an alternating current to flow through the
capacitor C
– The positive parts of this current flow through C, Th and the primary of the HV
transformer
– The negative parts of the current flow through C, D and the primary of the HV
transformer
RS resistor calculation
The Rs resistor allows, in addition with the capacitor C, the spark frequency to be adjusted
and the current from the mains to be limited. Its value shall allow the thyristor Th to fire even
in the worst case. In this case the system must fire with the lower RMS mains voltage value
while the breakdown voltage and current of the FLC are at the maximum.
The maximum Rs value is equal to:
R smax
=
(---V----A----C-----m-----i-n------------2----)---–-----[--V-----B---O----m-----a---x--------(--1-----+------α----T--------(---T----a--m-----b----–----2---5----)---)--]-
k IBO (1)
(1) See Figure 4
Figure 6. Spark frequency versus RS and C
F (Hz)
20
10
5
3
2
Vac=220Vrms, Vbo=225V, Tamb=25°C
C=0.47μF
C=2C.7=μ2F.2Cμ=F1.5μCF=1μF
C=3.3μF
1
4.7
6.8
10 12
Rs (k Ω )
15 18 22 27 30
The couple Rs/C can be chosen with the previous curve.
Keep in mind the Rs maximum limit for which the system would not work when the AC
4/11