Absolute Maximum Ratings(Note 1)
Supply Voltage
Input Voltage
Output Voltage
Operating Free Air Temperature Range
Storage Temperature Range
7V
5.5V
30V
0°C to +70°C
−65°C to +150°C
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Recommended Operating Conditions
Symbol
VCC
VIH
VIL
VOH
IOL
TA
Parameter
Supply Voltage
HIGH Level Input Voltage
LOW Level Input Voltage
HIGH Level Output Voltage
LOW Level Output Current
Free Air Operating Temperature
Min
4.75
2
0
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol
Parameter
Conditions
VI
Input Clamp Voltage
VCC = Min, II = −12 mA
ICEX
HIGH Level
VCC = Min, VO = 30V
Output Current
VIL = Max, VIH = Min
VOL
LOW Level
VCC = Min, IOL = Max
Output Voltage
VIH = Min, VIL = Max
IOL = 80 mA
VCC = Min
II
Input Current @ Max Input Voltage
VCC = Max, VI = 5.5V
IIH
HIGH Level Input Current
VCC = Max, VI = 2.4V
IIL
LOW Level Input Current
VCC = Max, VI = 0.4V
ICC
Supply Current
VCC = Max (Note 3)
Note 2: All typicals are at VCC = 5V, TA = 25°C.
Note 3: ICC is measured with all inputs grounded and all outputs OPEN.
Switching Characteristics
at VCC = 5V and TA = 25°C
Symbol
Parameter
tPLH
Propagation Delay Time
LOW-to-HIGH Level Output
tPHL
Propagation Delay Time
HIGH-to-LOW Level Output
Conditions
CL = 15 pF
RL = 100Ω
Nom
Max
Units
5
5.25
V
V
0.8
V
30
V
20
mA
70
°C
Typ
Min
Max
(Note 2)
−1.5
250
0.2
0.4
0.5
0.9
1
40
−1.6
43
70
Units
V
µA
V
mA
µA
mA
mA
Min
Max
Units
49.5
ns
49.5
ns
3
www.fairchildsemi.com