SAW Components
Low-Loss Filter for Mobile Communication
Data Sheet
Characteristics
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
T = +25 ˚C
ZS = 50 Ω
ZL = 50 Ω
Center frequency
min.
fC
—
typ.
1960,0
Maximum insertion attenuation
αmax
1930,0 ...1990,0 MHz
—
2,8
Amplitude ripple (p-p)
∆α
1930,0 ...1990,0 MHz
—
1,0
Input return loss
Output return loss
1930,0 ...1990,0 MHz
1930,0 ...1990,0 MHz
—
11
—
12
Attenuation
α
0,0
1700,0
2050,0
2400,0
4000,0
...1700,0
...1910,0
...2400,0
...4000,0
...6000,0
MHz
MHz
MHz
MHz
MHz
30
41
20
24
22
26
30
36
22
29
B9007
1960,0 MHz
max.
— MHz
3,3 dB
1,6 dB
7 dB
7 dB
— dB
— dB
— dB
— dB
— dB
3 Mar 18, 2004