ABSOLUTE MAXIMUM RATINGS
Table 6.
Parameter
Storage Temperature
Ambient Operating
Temperature
Input Supply Voltage1
Output Supply Voltage1
Input Voltage1
Output Voltage1
Input-Output Voltage2
Output Differential
Voltage3
Output DC Current
Common-Mode
Transients4
Symbol
TST
TA
VDD1
VDDA, VDDB
VIA, VIB
VOA, VOB
IOA, IOB
Min
−55
−40
−0.5
−0.5
−0.5
−0.5
−700
−20
−100
Max
+150
+105
+7.0
+27
VDDI + 0.5
VDDA + 0.5,
VDDB + 0.5
+700
700
+20
+100
Unit
°C
°C
V
V
V
V
VPEAK
VPEAK
mA
kV/μs
1 All voltages are relative to their respective ground.
2 Input-to-output voltage is defined as GNDA − GND1 or GNDB − GND1.
3 Output differential voltage is defined as GNDA − GNDB.
4 Refers to common-mode transients across any insulation barrier. Common-
mode transients exceeding the Absolute Maximum Ratings can cause latch-
up or permanent damage.
ADuM1230
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Ambient temperature = 25°C, unless otherwise noted.
Table 7. ADuM1230 Truth Table (Positive Logic)
VIA/VIB Input VDD1 State
DISABLE VOA/VOB Output
H
Powered
L
H
L
Powered
L
L
X
Unpowered X
L
X
Powered
H
L
Notes
Output returns to input state within 1 μs of VDDI power restoration.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. A | Page 5 of 12

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]