AD9882
Parameter
AC SPECIFICATIONS
Intra-Pair (+ to –) Differential
Input Skew (TDPS)
Channel-to-Channel Differential
Input Skew (TCCS)
Low-to-High Transition Time
for Data (DLHT)
Conditions
Test
Temp Level
Full IV
Full IV
Output Drive = High,
CL = 10 pF
Full IV
Output Drive = Med,
CL = 7 pF
Full IV
Output Drive = Low,
CL = 5 pF
Full IV
Low-to-High Transition Time for
DATACK (DLHT)
Output Drive = High,
CL = 10 pF
Full IV
Output Drive = Med,
CL = 7 pF
Full IV
Output Drive = Low,
CL = 5 pF
Full IV
High-to-Low Transition Time for
Data (DHLT)
Output Drive = High,
CL = 10 pF
Full IV
Output Drive = Med,
CL = 7 pF
Full IV
Output Drive = Low,
CL = 5 pF
Full IV
High-to-Low Transition Time for
DATACK (DHLT)
Data-to-Clock Skew4
Duty Cycle, DATACK4
DATACK Frequency (FCIP)
Output Drive = High,
CL = 10 pF
Full IV
Output Drive = Med,
CL = 7 pF
Full IV
Output Drive = Low,
CL = 5 pF
Full IV
Full IV
Full IV
Full VI
NOTES
1The typical pattern contains a grayscale area, Output Drive = High.
2DATACK Load = 10 pF, Data Load = 10 pF.
3The worst-case pattern contains a black and white checkerboard pattern, Output Drive = High.
4DRIVE STRENGTH = 11
Specifications subject to change without notice.
AD9882KST
Min
Typ
Max
360
1
2.2
2.5
3.2
1.0
1.6
2.1
2.2
1.9
1.7
1.0
1.0
1.4
–0.5
+2.0
40
46
50
25
112
Unit
ps
Clock
Period
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
%
MHz
REV. A