AD7298
TIMING SPECIFICATIONS
VDD = 2.8 V to 3.6 V; VDRIVE = 1.65 V to 3.6 V; VREF = 2.5 V internal; TA = −40°C to + 125°C, unless otherwise noted. Sample tested during
initial release to ensure compliance. All input signals are specified with tr = tf = 5 ns (10% to 90% of VDRIVE) and timed from a voltage level
of 1.6 V.
Table 2.
Parameter
tCONVERT
fSCLK1
tQUIET
t2
t3 1
t41
t5
t6
t71
t81
t9
t10
t11
t121
tPOWER-UP_PARTIAL
tPOWER-UP
Limit at TMIN, TMAX
t2 + (16 × tSCLK)
820
100
50
20
6
10
15
35
28
0.4 × tSCLK
0.4 × tSCLK
14
16/34
5
4
100
30
1
6
Unit
μs max
ns typ
μs max
kHz min
MHz max
ns min
ns min
ns max
ns max
ns max
ns min
ns min
ns min
ns min/max
ns min
ns min
ns min
ns max
μs max
ms max
Test Conditions/Comments
Conversion time
Each ADC channel VIN0 to VIN7, fSCLK = 20 MHz
Temperature sensor channel
Frequency of external serial clock
Frequency of external serial clock
Minimum quiet time required between the end of serial read and the start
of the next voltage conversion in repeat and nonrepeat mode.
CS to SCLK setup time
Delay from CS (falling edge) until DOUT three-state disabled
Data access time after SCLK falling edge
VDRIVE = 1.65 V to 3 V
VDRIVE = 3 V to 3.6 V
SCLK low pulse width
SCLK high pulse width
SCLK to DOUT valid hold time
SCLK falling edge to DOUT high impedance
DIN setup time prior to SCLK falling edge
DIN hold time after SCLK falling edge
TSENSE_BUSY falling edge to CS falling edge
Delay from CS rising edge to DOUT high impedance
Power-up time from partial power-down
Internal reference power-up time from full power-down
1 Measured with a load capacitance on DOUT of 15 pF.
Rev. B | Page 5 of 24