Programmable Linear Hall Effect Sensors with Analog Output
Available in a Miniature Thin Profile Surface Mount Package
For purposes of specification, the sensitivity drift due to package
hysteresis, SensPKG, is defined as:
SensPKG =
Sens(25°C)2 Sens(25°C)1
Sens(25°C)1
×
100%
,
(8)
where Sens(25°C)1 is the programmed value of sensitivity at TA
= 25°C, and Sens(25°C)2 is the value of sensitivity at TA = 25°C,
after temperature cycling TA up to 150°C, down to –40°C, and
back to up 25°C.
Linearity Sensitivity Error The 138x family is designed to
provide a linear output in response to a ramping applied magnetic
field. Consider two magnetic fields, B1 and B2. Ideally, the sen-
sitivity of a device is the same for both fields, for a given supply
voltage and temperature. Linearity error is present when there is a
difference between the sensitivities measured at B1 and B2.
Linearity Error is calculated separately for the positive
(LinERRPOS) and negative (LinERRNEG ) applied magnetic fields.
Linearity error (%) is measured and defined as:
LinERRPOS
=
⎜⎜1–
SensBPOS2
SensBPOS1
⎟⎟
×100%
,
LinERRNEG
=
⎜⎜1–
SSeennssBBNNEEGG12⎟⎟⎠⎞
×100%
,
(9)
where:
SensBx
=
|VOUT(Bx)
Bx
VOUT(Q)|
,
(10)
and BPOSx and BNEGx are positive and negative magnetic fields,
with respect to the quiescent voltage output such that
|BPOS2| > |BPOS1| and |BNEG2| > |BNEG1|. Then:
Symmetry error, SymERR (%), is measured and defined as:
SymERR
=
⎜⎜1–
SensBPOS
SensBNEG
⎟⎟ ×100%
,
(12)
where SensBx is as defined in equation 10, and BPOS and BNEG
are positive and negative magnetic fields such that |BPOS| = |BNEG|.
Ratiometry Error The A138x devices feature ratiometric output.
This means that the quiescent voltage output, VOUT(Q) , magnetic
sensitivity, Sens, and clamp voltage, VCLP(HIGH) and VCLP(LOW),
are proportional to the supply voltage, VCC. In other words, when
the supply voltage increases or decreases by a certain percent-
age, each characteristic also increases or decreases by the same
percentage. Error is the difference between the measured change
in the supply voltage relative to 5 V, and the measured change in
each characteristic.
The ratiometric error in quiescent voltage output, RatERRVOUT(Q)
(%), for a given supply voltage, VCC, is defined as:
RatERRVOUT(Q) = ⎜⎜1–
VOUT(Q)(VCC)
VCC
/
/
5VOVUT(Q)(5V)⎟⎟⎠⎞
×100%
.
(13)
The ratiometric error in magnetic sensitivity, RatERRSens (%), for
a given supply voltage, VCC, is defined as:
RatERRSens
=
⎜⎜1–
Sens(VCC) / Sens(5V)
VCC / 5 V
⎟⎟
×100%
.
(14)
The ratiometric error in the clamp voltages, RatERRCLP (%), for a
given supply voltage, VCC, is defined as:
LinERR = max( |LinERRPOS | , |LinERRNEG | ) . (11)
Symmetry Sensitivity Error The magnetic sensitivity of an
A138x device is constant for any two applied magnetic fields of
RatERRCLP
=
⎜⎜1–
VCLP(VCC) / VCLP(5V)
VCC / 5 V
⎟⎟
×
100%
.
(15)
equal magnitude and opposite polarities.
where VCLP is either VCLP(HIGH) or VCLP(LOW).