74VHC139
Table 8: Capacitive Characteristics
Test Condition
Value
Symbol
Parameter
TA = 25°C
-40 to 85°C -55 to 125°C Unit
CIN Input Capacitance
CPD Power Dissipation
Capacitance
(note 1)
Min. Typ. Max. Min. Max. Min. Max.
4 10
10
10 pF
26
pF
1) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without
load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. ICC(opr) = CPD x VCC x fIN + ICC/2 (per
Decoder)
Figure 4: Test Circuit
CL =15/50pF or equivalent (includes jig and probe capacitance)
RT = ZOUT of pulse generator (typically 50Ω)
Figure 5: Waveform - Propagation Delays For Inverting Outputs (f=1MHz; 50% duty cycle)
5/12