MBR12020 thru MBR120100
Figure 1
Typical Forward Characteristics
2000
1000
MBR12020-12045
MBR12060
600
400
200
Amps 100
60
25°C
MBR12080-120100
40
20
10
6
4
2
1
0.2 0.4 0.6 0.8 1.0 1.2
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
MCC
Figure 2
Forward Derating Curve
120
100
80
60
Amps
40
20
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
50 70
90 110
130 150
°C
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 3
Junction Capacitance
10000
6000
4000
2000
pF
1000
600
400
200
100
.1 .2
TJ=25°C
MBR12020-12045
MBR12060
MBR12080-120100
.4
12 4
Volts
10 20 40
Junction Capacitance - pF versus
Reverse Voltage - Volts
100 200 400
1000
www.mccsemi.com