Hamamatsu Photonics
FEATURES
• Quick Response
The response time of less than 20µs enables accurate measurement of the spot, even while it is moving at high speeds.
• Stable Measurement
The position data (X-Y coordinate voltages) of a light spot is obtained without being affected by signal current fluctuations from the PSD, enabling accurate position measurement regardless of fluctuations in the light intensity.
• Broad Spectral Response
The C7339 has a broad spectral range, from 300 to 1100 nm, enabling the detection of a variety of light sources, including lasers.
• High Resolution
The PSD employed in the sensor head is of the non-discrete type, which, contrary to a discrete-type sensor, has no insensitive area. This enables continuous measurement at a high resolution of 1/5000 (when using a recorder).
• Light Level Indicator