ABSOLUTE MAXIMUM RATINGS*
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND to VS
Differential Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . ± 6 V
Storage Temperature Range
R, RM, RT Packages . . . . . . . . . . . . . . . . –65°C to +150°C
Operating Temperature Range
AD8601/AD8602 . . . . . . . . . . . . . . . . . . . –40°C to +125°C
Junction Temperature Range
R, RM, RT Packages . . . . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature Range (Soldering, 60 sec) . . . . . . . . 300°C
ESD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 kV HBM
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Package Type
5-Lead SOT-23 (RT)
8-Lead SOIC (R)
8-Lead MSOP (RM)
JA*
JC
Unit
230
92
°C/W
158
43
°C/W
210
45
°C/W
*θJA is specified for worst-case conditions, i.e., θJA is specified for device in
socket for PDIP packages; θJA is specified for device soldered onto a circuit
board for surface mount packages.
ORDERING GUIDE
Model
AD8601ART
AD8601DRT
AD8602AR
AD8602DR
AD8602ARM
AD8602DRM
Temperature
Range
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
Package
Description
5-Lead SOT-23
5-Lead SOT-23
8-Lead SOIC
8-Lead SOIC
8-Lead MSOP
8-Lead MSOP
Package
Option
RT-5
RT-5
SO-8
SO-8
RM-8
RM-8
Branding
Information
AAA
AAD
ABA
ABD
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD8601/AD8602 features proprietary ESD protection circuitry, permanent damage may occur
on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–