INPUT TIMING REQUIREMENTS
Symbol
tRISE/FALL
Frequency
Duty Cycle
Parameter
Rise/Fall Times REF_IN input (0.8V to 2.0V)
Input Frequency REF_IN input Modes 0, 1, 2, 3, 4
Modes 5, 6, 7
Modes 8, 9, 10, 11, 12
Modes 13, 14, 15
Input Duty Cycle, REF_IN input
OUTPUT FREQUENCY SPECIFICATIONS
Mode
0, 1, 2, 3,4
Parameter
Operating
F, F Outputs
frequency
F/2 Outputs
F/3 Outputs
5, 6, 7
Operating
3F Outputs
frequency
F Outputs
8, 9, 10, 11, 12
Operating
2F Outputs
frequency
F Outputs
F/2 Outputs
13, 14, 15
Operating
4F Outputs
frequency
2F Outputs
F Outputs
Min.
—
50
16.7
25
12.5
25
Min.
50
25
16.7
50
16.7
50
25
12.5
50
25
12.5
Max.
3.0
100
33.3
50
25
75
Max.
100
50
33.3
100
33.3
100
50
25
100
50
25
Unit
ns
MHz
%
3267 tbl 09
Unit
MHz
3267 tbl 10
POWER SUPPLY CHARACTERISTICS
Symbol
∆ICC
ICCD
IC
Parameter
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply
Current(4)
Total Power Supply Current(5,6)
VCC = Max.
Test Conditions(1)
VIN = VCC –0.6V(3)
Min. Typ.(2) Max.
— 2.0 30
VCC = Max.
VIN = VCC F = 50Mhz —
72
All Outputs Open
VIN = GND
50% Duty Cycle
MODE 10
VCC = Max.
—
62
PLL_EN = 1, LOCK = 1, MODE 10
REF_IN frequency = 50MHz.
All outputs open
Unit
µA
µA/
MHz/
bit
mA
NOTES:
3267 tbl 08
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics.
2. Typical values are at VCC = 3.3V, +25°C ambient.
3. Per TTL driven input; all other inputs at VCC or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations. It is derived with Q frequency as the reference.
5. Values for these conditions are examples of the ICC formula. These limits are guaranteed but not tested.
6. IC = IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ∆ICC DHNT + ICCD (f) + ILOAD
ICC = Quiescent Current (ICCL, ICCH and ICCZ)
∆ICC = Power Supply Current for a TTL High Input
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
f = SYNC input frequency
ILOAD = Dynamic Current due to load.
9.9
5