Nexperia
74LVC1G02
Single 2-input NOR gate
Table 7. Static characteristics …continued
At recommended operating conditions. Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions
40 C to +85 C
Min Typ[1] Max
IOFF
power-off
leakage
current
VCC = 0 V; VI or VO = 5.5 V
-
0.1 2
ICC
ICC
supply current
additional
supply current
VI = 5.5 V or GND; IO = 0 A;
VCC = 1.65 V to 5.5 V
VCC = 2.3 V to 5.5 V;
VI = VCC 0.6 V; IO = 0 A;
per pin
-
0.1
4
-
5
500
CI
input
VCC = 3.3 V; VI = GND to VCC
capacitance
-
5
-
[1] All typical values are measured at VCC = 3.3 V and Tamb = 25 C.
11. Dynamic characteristics
40 C to +125 C Unit
Min
Max
-
2
A
-
4
A
-
500 A
-
-
pF
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for load circuit see Figure 9.
Symbol Parameter
Conditions
40 C to +85 C
Min
Typ[1]
Max
tpd
propagation delay A, B to Y; see Figure 8
[2]
VCC = 1.65 V to 1.95 V
1.0
3.2
8.0
VCC = 2.3 V to 2.7 V
0.5
2.2
5.5
VCC = 2.7 V
0.5
2.5
5.5
VCC = 3.0 V to 3.6 V
0.5
2.1
4.5
VCC = 4.5 V to 5.5 V
CPD
power dissipation VI = GND to VCC;
capacitance
VCC = 3.3 V
0.5
1.7
4.0
[3]
-
14
-
40 C to +125 C Unit
Min
Max
1.0
10.5 ns
0.5
7.0 ns
0.5
7.0 ns
0.5
6.0 ns
0.5
5.5 ns
-
- pF
[1] Typical values are measured at Tamb = 25 C and VCC = 1.8 V, 2.5 V, 2.7 V, 3.3 V and 5.0 V respectively.
[2] tpd is the same as tPLH and tPHL.
[3] CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD VCC2 fi N + (CL VCC2 fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL VCC2 fo) = sum of outputs.
74LVC1G02
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 12 — 29 November 2016
© Nexperia B.V. 2017. All rights reserved
6 of 19