Philips Semiconductors
Dual retriggerable monostable multivibrator
with reset
Product specification
74AHC123A;
74AHCT123A
SYMBOL PARAMETER
TEST CONDITIONS
WAVEFORMS
CL
Tamb (°C)
25
−40 to +85 −40 to +125 UNIT
MIN. TYP. MAX. MIN. MAX. MIN. MAX.
VCC = 4.5 to 5.5 V; note 1
trt
retrigger time;
CEXT = 100 pF;
50 pF − 60 −
−−
−
−
ns
nA to nB
REXT = 1 kΩ; see
Figs 8, 9 and 10
CEXT = 0.01 µF;
REXT = 1 kΩ; see
Figs 8, 9 and 10
− 1.5 −
−−
−
−
µs
Notes
1. Typical values are measured at VCC = 5.0 V and Tamb = 25 °C.
2. For CEXT ≥ 10 nF the typical value of the pulse width tW (µs) = REXT (kΩ) × CEXT (nF).
2000 Mar 15