Si7013-A20
5.2. Reading and Writing User Registers
There are three user registers on the Si7013 that allow the user to set the configuration of the Si7013, the
procedure for accessing these registers is set out below. The checksum byte is not supported after reading a user
register.
Slave
S
W
Address
Sequence to read a register
Read Reg
A
A
Cmd
Slave
Sr Addres R
s
Sequence to write a register
A
ns Read
ig NA
P
Des Data
Slave
Write Reg
S
W
A
A
Write Data
A
P
Address
Cmd
ew 5.3. Measuring Analog Voltage
The analog voltage input pins can accept voltage inputs within the ranges shown in Table 16. VREFP is internally
N connected to VDDA or to an internal 1.25 V reference voltage.
r Table 16. Analog Input Ranges
fo VINP Input Range
Min
Max
VINN Input Range
Min
Max
ed Buffered Input
d Unbuffered Input
0.35 V
0V
VDD–0.35 V
VDD
0.35 V
0V
VDD–0.35 V
VDD
n The voltage conversion output is a signed 16-bit integer that will vary from –32768 to 32767 as the input (VINP–
e VINN) goes from –V to +V. For best performance, it is recommended that |VINP–VINN| be limited to Vref/2. With
minor degradation in performance, this can be extended to 0.8*Vref. The checksum option for voltage mode
Not Recomm conversions is not supported.
Rev. 1.4
25