Nexperia
74ALVC08
Quad 2-input AND gate
Symbol Parameter
Conditions
II
IOFF
ICC
ΔICC
CI
input leakage current
power-off
leakage current
supply current
additional
supply current
input capacitance
VCC = 3.6 V; VI = 3.6 V or GND
VCC = 0 V; VI or VO = 3.6 V
VCC = 3.6 V; VI = VCC or GND; IO = 0 A
per input pin; VCC = 3.0 V to 3.6 V;
VI = VCC - 0.6 V; IO = 0 A
[1] All typical values are measured at VCC = 3.3 V (unless stated otherwise) and Tamb = 25 °C.
10 Dynamic characteristics
Table 7. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V). For test circuit, see Figure 8.
Symbol Parameter
Conditions
tpd
propagation delay nA, nB to nY; see Figure 7
[2]
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
CPD
power dissipation
per gate; VI = GND to VCC; VCC = 3.3 V [3]
capacitance
[1] Typical values are measured at Tamb = 25 °C and VCC = 1.8 V, 2.5 V, 2.7 V and 3.3 V respectively
[2] tpd is the same as tPHL and tPLH.
[3] CPD is used to determine the dynamic power dissipation (PD in μW).
PD = CPD × VCC2 × fi × N + Σ(CL × VCC2 × fo) where:
fi = input frequency in MHz
fo = output frequency in MHz
CL = output load capacitance in pF
VCC = supply voltage in Volts
N = number of inputs switching
Σ(CL × VCC2 × fo) = sum of the outputs
Tamb = -40 °C to +85 °C
Min
Typ [1]
Max
-
±0.1
±5
-
±0.1
±10
-
0.2
20
-
5
750
-
3.5
-
Tamb = -40 °C to +85 °C
Min
Typ [1]
Max
1.2
2.7
5.3
1.0
1.9
3.2
-
2.2
3.0
1.2
2.0
2.9
-
24
-
Unit
μA
μA
μA
μA
pF
Unit
ns
ns
ns
ns
pF
74ALVC08
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 5 October 2017
© Nexperia B.V. 2017. All rights reserved.
5 / 14