Si7005
Table 3. I2C Interface Specifications*
2.1 VDD 3.6 V; TA = 0 to 70 °C (F grade) or –40 to +85 °C (G grade) unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ
Hysteresis
VHYS High-to-low versus low-to- 0.05 x VDD —
high transition
SCLK Frequency
fSCL
—
—
SCL high time
tSKH
0.6
—
SCL low time
tSKL
1.3
—
Start hold time
tSTH
0.6
—
Start setup time
tSTS
0.6
—
Stop setup time
tSPS
0.6
—
Bus free time
tBUF
Between Stop and Start
1.3
—
SDA setup time
tDS
100
—
SDA hold time
tDH
100
—
SDA valid time
tVD;DAT From SCL low to data valid
—
—
SDA acknowledge valid time tVD;ACK From SCL low to data valid
—
—
*Note: All values are referenced to VIL and/or VIH.
Max Unit
—
V
400 kHz
—
µs
—
µs
—
µs
—
µs
—
µs
—
µs
—
ns
—
ns
0.9
µs
0.9
µs
1/fSCL
tSKH
tSKL
SCL
tBUF
tSTH
tDS
tDH
tSPS
SDA
Start Bit
tSTS
D7
D6
D5
D0
R/W
ACK
Figure 1. I2C Interface Timing Diagram
tVD : ACK
Stop Bit
6