Data Sheet
ADuM1400/ADuM1401/ADuM1402
PACKAGE CHARACTERISTICS
Table 8.
Parameter
Resistance (Input to Output)1
Capacitance (Input to Output)1
Input Capacitance2
IC Junction to Case Thermal Resistance, Side 1
IC Junction to Case Thermal Resistance, Side 2
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ
1012
2.2
4.0
33
28
Max Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
1 Device is considered a 2-terminal device; Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14,
Pin 15, and Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM1400/ADuM1401/ADuM1402 are approved by the organizations listed in Table 9. Refer to Table 14 and the Insulation Lifetime
section for details regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 9.
UL
Recognized Under
UL 1577 Component
Recognition
Program1
CSA
Approved under
CSA Component
Acceptance Notice 5A
VDE
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-122
Single Protection,
2500 V rms Isolation
Voltage
File E214100
Basic insulation per
CSA 60950-1-03 and
IEC 60950-1, 780 V rms
(1103 V peak) maximum
working voltage
Reinforced insulation
per CSA 60950-1-03 and
IEC 60950-1, 390 V rms
(551 V peak) maximum
working voltage
File 205078
Reinforced insulation,
560 V peak
File 2471900-4880-0001
CQC
Approved under
CQC11-471543-2012
Basic Insulation per
GB4943.1-2011, 415 V rms
(588 V peak) maximum
working voltage, tropical
climate, altitude ≤ 5000 m
File CQC14001114900
TÜV
Approved according to
IEC 61010-1:2001 (2nd Edition),
EN 61010-1:2001 (2nd Edition),
UL 61010-1:2004, and
CSA C22.2.61010.1:2005
Reinforced insulation, 400 V rms
maximum working voltage
Certificate U8V 05 06 56232 002
1 In accordance with UL 1577, each ADuM1400/ADuM1401/ADuM1402 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage
detection limit = 5 µA).
2 In accordance with DIN V VDE V 0884-10, each ADuM1400/ADuM1401/ADuM1402 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 10.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
L(PCB)
CTI
Value
2500
7.8 min
7.8 min
8.3 min
0.017 min
>400
II
Unit
V rms
mm
mm
mm
mm
V
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Measured from input terminals to output terminals,
shortest distance through air, and line of sight, in the
PCB mounting plane
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. L | Page 19 of 31