9. Recommended operating conditions
Table 5. Recommended operating conditions
Symbol Parameter
Conditions
VCC
VI
VSW
Tamb
t/V
supply voltage
input voltage
switch voltage
ambient temperature
input transition rise and fall
rate
see Figure 7
and Figure 8
VCC GND
VCC VEE
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 10.0 V
74HC4052-Q100
Min Typ Max
2.0
2.0
GND
VEE
40
-
-
-
-
5.0
5.0
-
-
+25
-
1.67
-
-
10.0
10.0
VCC
VCC
+125
625
139
83
31
74HCT4052-Q100 Unit
Min Typ Max
4.5
2.0
GND
VEE
40
-
-
-
-
5.0
5.0
-
-
+25
-
1.67
-
-
5.5
10.0
VCC
VCC
+125
-
139
-
-
V
V
V
V
C
ns/V
ns/V
ns/V
ns/V
12
VCC − GND
(V)
8
mnb044
12
VCC − GND
(V)
10
8
mnb045
operating area
4
6
operating area
4
2
0
0
4
8
12
VCC − VEE (V)
0
0
4
8
12
VCC − VEE (V)
Fig 7. Guaranteed operating area as a function of the Fig 8. Guaranteed operating area as a function of the
supply voltages for 74HC4052-Q100
supply voltages for 74HCT4052-Q100
74HC_HCT4052_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 22 November 2012
© Nexperia B.V. 2017. All rights reserved