SEME
LAB
2N5430
OFF CHARACTERISTICS
Parameter
BVCEO (sus)* Collector – Emitter
Sustaining Voltage
ICBO
Collector Cutoff Current
ICEX
Collector Cutoff Current
ICBO
IEBO
Collector Cutoff Current
Emitter Cutoff Current
Test Conditions
IC = 50mA , IB = 0
VCE = 90V , IB = 0
VCE = 90V , VEB(off) = 1.5V
VCE = 90V , VEB(off) = 1.5V , TC = 150°C
VCB = Rated VCB , IE = 0
VBE = 6V , IC = 0
Min Max Unit
100
V
100
mA
10
mA
1.0
mA
10
mA
100
mA
ON CHARACTERISTICS
Parameter
hFE*
DC Current Gain
VCE(sat)*
VBE(sat)*
Collector – Emitter
Saturation Voltage
Base – Emitter
Saturation Voltage
Test Conditions
IC = 500mA , VCE = 2V
IC = 2A , VCE = 2V
IC = 5A , VCE = 2V
IC = 2A , IB = 0.2A
IC = 7A , IB = 0.7A
IC = 2A , IB = 0.2A
IC = 7A , IB = 0.7A
Min Max Unit
60
60
240
—
40
0.7
V
1.2
1.2
V
2.0
DYNAMIC CHARACTERISTICS
Parameter
Current Gain
fT
Bandwidth Product
Cob
Output Capacitance
Cib
Input Capacitance
Test Conditions
IC = 500 mA, VCE = 10V, f = 10 MHz
VCB = 10V, IE = 0, f = 100 kHz
VBE = 2V, IC = 0, f = 100 kHz
Min Max Unit
30
MHz
250
pF
1000 pF
SWITCHING CHARACTERISTICS
Parameter
Test Conditions
td
Delay Time
tr
Rise Time
ts
Storage Time
tf
Fall Time
VCC = 40V, VEB(off) = 3V
IC = 2A, IB1 = 200mA
VCC = 40V, IC = 2A
IB1 = IB2 = 200mA
* Pulse Test: Pulse width = 300 ms, Duty Cycle = 2.0 %
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Min Max Unit
100
ns
100
ns
2.0
ms
200
ns
Prelim. 1/94