FIGURE 13: WIDE RANGE LOW-CURRENT AMMETER
OP-41
'5V
alA
112 MAT-02EH
A12
4!<!!
A8
10nA 511\1
r INPUT
C1
lOOp
C2
2llF
R2
2.4Mil
A1
4.7kl>
AS
2kH
R3
alS
112MAT-02EH
3kU
01
IN914
&1
1ltA
02
LM1l3
Ala
51W
OBS The voltage driving the divider is obtained from a 1.22V low
voltage reference diode (LM113) through a 2N2222 transistor
O and resistor string. The voltage across the divider varies with
absolute temperature, keeping the multiplier constant.
L Calibration is simple, requiring only one adj ustment. R4 is used
E to adjust full scale deflection with a 1pA input current. This will
give maximum accuracy over the operating range of currents.
TE The low Vosand exceptionally good log conformance of the
FIGURE 14: SETTLING-TIME TEST CIRCUIT
,'5V
~O"lJt
4.99k!l 1%
MAT-O2assure high accuracy over the full 6 decade operating
range.
Figure 14 is the test circuit used to measure the settling time.
This circuit uses the "false sum-node" technique. When the
system is Initially set up. the 2000. pot is adjusted until the DC
output voltage to the scope is unchanged when the input is
changed from +10Vto -10V.The 2N4416 FET buffer isolates the
+15V
2N44l6
4.99kH'"
200n
4.99kU
-15V
1%
Vour
~O.'ltf
sum node from the scope probe load capacitance. The pulse
generator must be properly terminated and have ringing below
the expected error signal. (2.5mV in a 5V pulse for 0.1%
overshoot measurement.)