ADT7421
ELECTRICAL CHARACTERISTICS (TA = −40°C to +125°C, VDD = 3.0 V to 3.6 V, unless otherwise noted)
Parameter
Power Supply
Conditions
Min
Typ
Max Unit
Supply Voltage, VDD
Average Operating Supply Current, IDD
Standby Mode Supply Current
Power-On-Reset Threshold
0.0625 Conversions/Sec Rate (Note 1)
−40°C ≤ TA ≤ +85°C
−40°C ≤ TA ≤ +125°C
3.0
3.30
3.6
V
3.0
4.0
mA
10
mA
20
1.0
2.8
V
Temperature−To−Digital Converter
Local Sensor Accuracy
Resolution
0°C ≤ TA ≤ +125°C
±2.75 °C
1.0
°C
Remote Transistor Sensor Accuracy
Resolution
+40°C ≤ TA ≤ +85°C, +60°C ≤ TD ≤ +110°C (Note 2)
+25°C ≤ TA ≤ +85°C, +60°C ≤ TD ≤ +110°C (Note 2)
TA = +40°C, +60°C ≤ TD ≤ +110°C (Note 2)
±2.5
°C
±3.25
±1.75
0.25
°C
Remote Sensor Source Current
The range of source currents provided to the external
10 to
mA
thermal transistor for temperature measurements.
360
Conversion Time
From stop bit to conversion complete, one-shot mode
184
ms
with averaging switched on.
One-shot mode with averaging off.
20
Maximum Series Resistance Cancelled Resistance split evenly on both the D+ and D– inputs.
50
W
Open−Drain Digital Outputs (THERM, ALERT/THERM2, SDA)
Output Low Voltage, VOL
High Level Output Leakage Current,
IOH
SMBus Interface (Note 3)
IOUT = −6.0 mA
VOUT = VDD
0.2
V
0.1
1.0
mA
Logic Input High Voltage, VIH
SCL, SDA
3.0 V ≤ VDD ≤ 3.6 V
2.1
V
Logic Input Low Voltage, VIL
SCL, SDA
3.0 V ≤ VDD ≤ 3.6 V
0.8
V
Hysteresis
500
mV
SDA Output Low Voltage, VOL
Logic Input Current, IIH, IIL
SMBus Input Capacitance,
SCLK, SDATA
IOUT = −6.0 mA
0.4
V
−1.0
+1.0
mA
10
pF
SMBus Clock Frequency
400
kHz
SMBus Timeout (Note 4)
User programmable
25
300
ms
SCLK Falling Edge to SDATA Valid
Time
Master clocking in data
1.0
ms
1. See Table 4 for information on other conversion rates.
2. Guaranteed by characterization, but not production tested.
3. See SMBus Timing Specifications section for more information.
4. Disabled by default. Detailed procedures to enable it are in the Serial Bus Interface section of this datasheet.
http://onsemi.com