ADM6821/ADM6822/ADM6823/ADM6824/ADM6825
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
RESET 1
5 VCC
ADM6821
GND 2 TOP VIEW
(Not to Scale)
MR 3
4 WDI
Figure 2. ADM6821 Pin Configuration
RESET 1
5 VCC
ADM6824
GND 2 TOP VIEW
(Not to Scale)
RESET 3
4 WDI
Figure 4. ADM6824 Pin Configuration
RESET 1
5 VCC
ADM6822/
GND 2 ADM6823
TOP VIEW
MR 3 (Not to Scale) 4 WDI
Figure 3. ADM6822/ADM6823 Pin Configuration
RESET 1
5 VCC
ADM6825
GND 2 TOP VIEW
(Not to Scale)
RESET 3
4 MR
Figure 5. ADM6825 Pin Configuration
Table 4. Pin Function Descriptions
Pin No. Name
1
RESET
(ADM6822/ADM6823/ADM6824/ADM6825)
RESET (ADM6821)
2
GND
3
MR (ADM6821/ADM6822/ADM6823)
RESET (ADM6824/ADM6825)
4
WDI
(ADM6821/ADM6822/ADM6823/ADM6824)
MR (ADM6825)
5
VCC
Description
Active-Low Reset Output. Asserted whenever VCC is below the reset threshold, VTH.
Open-Drain Output Stage for the ADM6822.
Push-Pull Output Stage for the ADM6823/ADM6824/ADM6825.
Active-High Push-Pull Reset Output.
Ground.
Manual Reset Input. This is an active-low input, which, when forced low for at
least 1 μs, generates a reset. It features a 50 kΩ internal pull-up.
Active-High Push-Pull Reset Output.
Watchdog Input. Generates a reset if the voltage on the pin remains low or high
for the duration of the watchdog timeout. The timer is cleared if a logic transition
occurs on this pin or if a reset is generated.
Manual Reset Input.
Power Supply Voltage Being Monitored.
Rev. 0 | Page 6 of 12