Dual 4-bit synchronous binary counter
7. Functional description
Table 3.
nCP0
L
X
H
X
Function table[1]
nCP1
H
X
L
X
nMR
L
L
L
L
L
L
H
Mode
counter advances
counter advances
no change
no change
no change
no change
nQ0 to nQ3 = LOW
[1] H = HIGH voltage level; L = LOW voltage level; X = don’t care; = positive-going transition; = negative-going transition.
8. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
Conditions
Min
Max Unit
VCC
IIK
IOK
IO
ICC
IGND
Tstg
Ptot
supply voltage
input clamping current
output clamping current
output current
supply current
ground current
storage temperature
total power dissipation
VI < 0.5 V or VI > VCC + 0.5 V
VO < 0.5 V or VO > VCC + 0.5 V
VO = 0.5 V to VCC + 0.5 V
SO16 and (T)SSOP16 package
0.5
-
-
-
-
50
65
[1]
-
+7.0 V
20 mA
20 mA
25 mA
50 mA
-
mA
+150 C
500 mW
[1] For SO16 package: above 70 C the value of Ptot derates linearly at 8 mW/K.
For (T)SSOP16 packages: above 60 C the value of Ptot derates linearly at 5.5 mW/K.
74HC_HCT4520
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 — 10 May 2016
© Nexperia B.V. 2017. All rights reserved