ZXCT1008
Where Rload represents any load including DC
motors, a charging battery or further circuitry that
requires monitoring, Rsense can be selected on
specific requirements of accuracy, size and power
rating.
An additional resistor, Rlim can be added in series
with Rout (figure 1.0), to limit the current from Iout.
Any circuit connected to Vout will be protected from
input voltage transients. This can be of particular
use in automotive applications where load dump
and other common transients need to be
considered. The zener Z1 provides additional
protection for local dump, reverse battery and high
voltage transient incidents.
Assuming the worst case condition of Vout = 0V;
providing a low impedance to a transient, the
minimum value of Rlim is given by:-
Rlim(min)
=
Vpk
Vmax
Ipk
Vpk = Peak transient voltage to be withstood
Vmax = Maximum working Voltage = 20V
Ipk = Peak output current = 40mA
TYPICAL AUTOMOTIVE CIRCUIT APPLICATION
Figure 1.0
ZXCT1009 with additional current limiting Resistor Rlim
and zener Z1
The maximum value of Rlim is set by Vin(min),
Vout(max) and the dropout voltage (see transfer
characteristic on page 3) of the ZXCT1009 :-
Rlim(max)
=
Rout[Vin(min) (Vdp + Vout(max))]
Vout (max)
Vin(min) = Minimum Supply Operating Voltage
Vdp = Dropout Voltage
Vout (max) = Maximum Operating Output Voltage
ISSUE 3 - FEBRUARY 2007