Micrel
ClockWorks™
SY10EL38/L
SY100EL38/L
DC ELECTRICAL CHARACTERISTICS(1)
VEE = VEE (Min.) to VEE (Max.); VCC = GND
Symbol
Parameter
TA = –40°C
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
IEE
Power Supply Current
mA
10EL 35 50 65 35 — 65 35 — 65 35 — 65
100EL 35 50 65 35 — 65 35 — 65 35 — 75
VBB
Output Reference
V
Voltage
10EL -1.43 — -1.30 -1.38 — -1.27 -1.35 — -1.25 -1.31 — -1.19
100EL -1.38 — -1.26 -1.38 — -1.26 -1.38 — -1.26 -1.38 — -1.26
IIH
Input High Current
— — 150 — — 150 — — 150 — — 150 µA
NOTE:
1. Parametric values specified at:
5 volt Power Supply Range
3 volt Power Supply Range
100EL38 Series:
10EL38 Series
10/100EL38L Series:
-4.2V to -5.5V.
-4.75V to -5.5V.
-3.0V to -3.8V.
AC ELECTRICAL CHARACTERISTICS(1)
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = -40°C
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
fMAX
Maximum Toggle Frequency 1000 — — 1000 — — 1000 — — 1000 — — MHz
tPLH
tPHL
tskew
Propagation Delay to Output
CLK ➝ Output (Diff.) 950
CLK ➝ Output (S.E.) 900
MR ➝ Output
600
Within-Device Skew(2) Q0 — Q3 —
All —
— 1150 950 — 1150 970
— 1200 900 — 1200 920
— 900 600 — 900 600
— 50 — — 50 —
— 75 — — 75 —
ps
— 1170 1050 — 1250
— 1220 1000 — 1300
— 900 600 — 900
— 50 — — 50 ps
— 75 — — 75
tS
tH
VPP
VCMR
Part-to-Part
Q0 — Q3 (Diff.) —
All —
— 200 — — 200 — — 200 —
— 240 — — 240 — — 240 —
— 200
— 240
Set-up Time
EN ➝ CLK 300 150 — — 150 — — 150 — — 150 — ps
DIVSEL ➝ CLK 300 — — — — — — — — — — —
Hold Time
CLK ➝ EN 400 150 — 400 150 — 400 150 — 400 150 — ps
CLK ➝ DIVSEL 400 200 — 400 200 — 400 200 — 400 200 —
Minimum Input Swing(3) CLK 250 — — 250 — — 250 — — 250 — — mV
Common Mode Range(4) CLK –1.3 — –0.4 –1.4 — –0.4 –1.4 — –0.4 –1.4 — –0.4 V
tRR
Reset Recovery Time
— — 100 — — 100 — — 100 — — 100 ps
tPW
Minimum Pulse Width
CLK 800 — — 800 — — 800 — — 800 — — ps
MR 700 — — 700 — — 700 — — 700 — —
tr
Output Rise/Fall Times
Q 280 — 550 280 — 550 280 — 550 280 — 550 ps
tf
(20% —80%)
NOTES:
1. Parametric values specified at:
5 volt Power Supply Range 100EL38 Series:
-4.2V to -5.5V.
10EL38 Series
-4.75V to -5.5V.
3 volt Power Supply Range 10/100EL38L Series: -3.0V to -3.8V.
2. Skew is measured between outputs under identical transitions.
3. Minimum input swing for which AC parameters are guaranteed. The device will function reliably with differential inputs down to 100mV.
4. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V. The lower end of the CMR range varies 1:1 with VEE. The numbers in the spec table
assume a nominal VEE = –3.3V. Note for PECL operation, the VCMR (min) will be fixed at 3.3V – IVCMR (min)I.
2