STK800
1
Electrical ratings
Electrical ratings
Table 2. Absolute maximum ratings
Symbol
Parameter
VDS
Drain-source voltage (VGS = 0)
VGS (1) Gate-source voltage
VGS(2) Gate-source voltage
ID (4)
Drain current (continuous) at TC = 25°C
ID
Drain current (continuous) at TC = 100°C
IDM (3) Drain current (pulsed)
PTOT (4) Total dissipation at TC = 25°C
Derating factor
EAS (5) Single pulse avalanche energy
Tj
Operating junction temperature
Tstg
Storage temperature
1. Continuous mode
2. Guaranteed for test time <15ms
3. Pulse width limited by package
4. When mounted on FR-4 board of 1inch2, 2 oz Cu and ≤10sec
5. Starting TJ = 25°C, ID = 10A, VDD = 25V
Value
30
± 16
± 18
20
12.5
80
5.2
0.0416
1
-55 to 150
Table 3. Thermal data
Symbol
Parameter
Typ.
Rthj-amb(1) Thermal resistance junction-amb
20
Rthj-c(2) Thermal resistance junction-case (top drain)
1
Rthj-c(3) Thermal resistance junction-case (source)
2.8
1. When mounted on FR-4 board of 1inch2, 2 oz Cu and ≤10sec
2. Steady state
3. Measured at source pin when the device is mounted on FR-4 board in steady state
Max.
24
1.2
3.4
Unit
V
V
V
A
A
A
W
W/°C
J
°C
Unit
°C/W
°C/W
°C/W
3/16