Philips Semiconductors
BCD up/down counter
FUNCTION TABLE
MR PL
L
H
L
L
L
L
L
L
HX
UP/DN
X
X
L
H
X
CE CP
MODE
X
X parallel load
H X no change
L
count down
L
count up
X
X reset
Notes
1. H = HIGH state (the more positive voltage)
L = LOW state (the less positive voltage)
X = state is immaterial
= positive-going transition
Product specification
HEF4510B
MSI
Fig.5 State diagram.
Logic equation for terminal count:
TC = CE ⋅ { (UP/DN) ⋅ O0 ⋅ O3 + ( UP ⁄ DN ) ⋅ O0 ⋅ O1 ⋅ O2 ⋅ O3}
A.C. CHARACTERISTICS
VSS = 0 V; Tamb = 25 °C; input transition times ≤ 20 ns
Dynamic power
dissipation per
package (P)
VDD
V
TYPICAL FORMULA FOR P (µW)
5
1000 fi + ∑ (foCL) × VDD2
where
10
4500 fi + ∑ (foCL) × VDD2
fi = input freq. (MHz)
15
11 200 fi + ∑ (foCL) × VDD2
fo = output freq. (MHz)
CL = load capacitance (pF)
∑ (foCL) = sum of outputs
VDD = supply voltage (V)
January 1995
5