POWER MANAGEMENT
Electrical Characteristics (Cont.)
Unless specified: VCC = 12V; CL = 100pF; TA = -40°C to 105°C
Parameter
Test Conditions
VCC Under Voltage Lockout
Turn-on
Turn-off
Line Under Voltage Lockout
Start Threshold
RTOP = 14kΩ, RBOT = 10kΩ
Hysteresis
RTOP = 14kΩ, RBOT = 10kΩ
Soft Start
Internal Soft Start Ramp
Soft Start Duration
Soft Start Delay
Rcs = 1kΩ
(See formula in the Application
Information Soft Start section)
Oscillator
Oscillator Frequency
Oscillator Ramp
Rosc = 11kΩ, Cosc = 200pF
RC pin to GND capacitance
Oscillator Frequency Range
Sync/CLOCK
Clock SYNC Threshold
Sync Frequency Range
Bandgap
Reference Voltage
Reference Current
Overall
Startup Current
Operating Supply Current
VCC Zener Shunt Voltage
VCC < start threshold
FB = 0V, CS = 0V
IDD = 10mA
SC4808C
Min
Typ
Max
Unit
7.5
8
8.5
V
6.5
7
7.5
V
-3% VREF +3%
V
5.6% of
VREF
mV
200
µs/V
12
µs
140
µs
450
500
550
KHz
VREF/2
V
+0.25
22
pF
50
1000
KHz
1.0
V
Fosc*1.3 KHz
2.970 3.125 3.280
V
5
mA
150
µA
7
mA
16
V
2006 Semtech Corp.
3
www.semtech.com