RHFL4913XX15 - RHFLXX25 - RHFLXX33 - RHFLXX50
Device description
5.6
OCM pin
Goes low when current limiter starts to be active, otherwise VOCM = VI. It is bufferized and
can sink 10 mA. OCM pin is internally pulled-up by a 5 kΩ resistor. Not available in 3 pin
packages.
5.7
Alternate to
RHFL4913 fixed (& custom) voltages replace all 3-terminal industry devices, providing
essential benefits
- Lower drop-out
- High radiation performance
- Better SVR
- Saving the high stability external setting resistors.
9/19