PM6600
3
Electrical data
Electrical data
3.1
Maximum rating
Table 3. Absolute maximum ratings (1)
Symbol
Parameter
Value
Unit
VAVCC
VLDO5
AVCC to SGND
LDO5 to SGND
PGND to SGND
-0.3 to 6
-0.3 to 6
-0.3 to 0.3
VIN
VIN to PGND
VLX
LX to SGND
LX to PGND
RILIM, BILIM, SYNC, OVSEL, SS to SGND
EN, DIM, FSW, MODE, FAULT to SGND
-0.3 to 40
-0.3 to 40
-0.3 to 40
-0.3 to
V
VAVCC + 0.3
-0.3 to 6
ROWx to PGND/ SGND
-0.3 to 40
SLOPE to VIN
SLOPE to SGND
VIN - 0.3 to
VIN + 6
-0.3 to 40
Maximum LX RMS current
2.0
A
PTOT
Power dissipation @=25°C
2.3
W
Maximum withstanding voltage range test condition:
CDF-AEC-Q100-002- “Human Body Model”
±1000
V
acceptance criteria: “Normal Performance”
1. Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the
device. Exposure to absolute maximum rated conditions for extended periods may affect device reliability.
3.2
Thermal data
Table 4. Thermal data
Symbol
Parameter
RthJA
TSTG
TJ
TA
Thermal resistance junction to ambient
Storage temperature range
Junction operating temperature range
Operating ambient temperature range
Value
42
-50 to 150
-40 to 125
-40 to 85
Unit
°C/W
°C
°C
°C
7/43