datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

YAC520 View Datasheet(PDF) - Yamaha Corporation

Part Name
Description
MFG CO.
YAC520
Yamaha
Yamaha Corporation 
YAC520 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
YAC520
Volume Setting
In zero crossing mode (ZCEN=H), the volume value is changed when one zero crossing is detected after
the rise of CSN. The volume value is changed also when no zero crossing is detected for 20 ms. In normal
mode (ZCEN=L), zero crossing detection is not performed and volume value is changed immediately
after the rise of CSN.
The input codes and volumes values are related as described in the following table.
Input Code
(Left/Right Channel)
11111111
11111110
11010111
11000100
10111111
00000010
00000001
00000000
L(R)IN1=L(R)IN2
L(R)IN2=GND
L(R)IN1=GND
Gain or Attenuation (dB) Gain or Attenuation (dB) Gain or Attenuation (dB)
+32.0
+31.5
+12.0
+2.5
0
94.5
95.0
MUTE
+29.5
+29.0
+9.5
0
2.5
97.0
97.5
MUTE
+20.0
+19.5
0
9.5
12.0
106.5
107.0
MUTE
MUTE
Writing 0000h into register enables mute. The time mute is enabled varies between zero crossing mode
(ZCEN=H) and normal mode (ZCEN=L) as described above.
8

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]