PRELIMINARY
KL5KUSB121
USB to 10/100 Ethernet Controller
2. Recommended Operating Conditions
Table 5.2 Recommended Operating Conditions
Parameter
Symbol Min Typ
Operating supply voltage
Vdd
3.0
–
Operating ambient temperature Ta
0
–
Max Unit
3.6 V
70 °C
3. I/O Electrical DC Characteristics (Over Recommended Range)
Table 3.1 DC Characteristics (over recommended range)
Parameter
Symbol Min Typ Max Unit
Test Conditions
Input low voltage
VIL
–
–
0.8 V
Input high voltage
VIH 2.0 –
–
V
Input low current
IIL
–10 –
10 uA VIN = Gnd
Input high current
IIH –10 –
10 uA VIN = Vdd
Output low voltage
VOL
–
–
0.4 V IOL = 4mA
Output high voltage
VOH 2.4 –
–
V IOH = –4mA
3-state leak current
IOZ –10 –
10 uA VOH = Gnd or VOL =
Vdd
Active pull-up current
IPU –25 –66 –160 uA VIN = Gnd or VOH =
Gnd
VIN = Gnd or Vdd
Standby current
IDDS
–
80 100 uA No inputs are cycling.
Outputs open.
Same conditions as
Suspend current
ISUSP – 350 450 uA IDDS
except for CLKI input
buffer 48MHz toggling.
IDDOP1
Outputs open.
dynamic operating
(in busy) – 80 100 mA Vdd = Max.
current
IDDOP2
FCLKI = FMAX (
(in idle) – 40 50 mA 48MHz )
Input capacitance
Output capacitance
CIN
–
–
15 pF Fpin=1MHz, VIN =
Gnd.
COUT –
–
15 pF Vin = 100 mVrms
Ver. 1.1
Kawasaki LSI • 2570 North First Street • Suite 301 • San Jose, CA 95131 • Tel: (408) 570-0555 • Fax: (408) 570-0567 • www.klsi.com