IDT2308
3.3V ZERO DELAY CLOCK MULTIPLIER
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES
OPERATING CONDITIONS- COMMERCIAL
Symbol
Parameter
Test Conditions
VDD
Supply Voltage
TA
Operating Temperature (Ambient Temperature)
CL
Load Capacitance below 100MHz
Load Capacitance from 100MHz to 133MHz
CIN
Input Capacitance(1)
NOTE:
1. Applies to both REF and FBK.
Min.
Max.
Unit
3
3.6
V
0
70
°C
—
30
pF
—
15
pF
—
7
pF
DC ELECTRICAL CHARACTERISTICS - COMMERCIAL
Symbol
Parameter
Conditions
Min.
Typ.(1) Max.
Unit
VIL
Input LOW Voltage Level
—
—
0.8
V
VIH
Input HIGH Voltage Level
2
—
—
V
IIL
Input LOW Current
VIN = 0V
—
—
50
μA
IIH
Input HIGH Current
VIN = VDD
—
—
100
μA
VOL
Output LOW Voltage
IOL = 8mA (-1, -2, -3, -4)
—
—
0.4
V
IOL = 12mA (-1H, -2H, -5H)
VOH
Output HIGH Voltage
IOH = -8mA (-1, -2, -3, -4)
2.4
—
—
V
IOH = -12mA (-1H, -2H, -5H)
IDD_PD
Power Down Current
REF = 0MHz (S2 = S1 = H)
—
—
12
μA
100MHz CLKA (-1, -2, -3, -4)
—
—
45
100MHz CLKA (-1H, -2H, -5H) —
—
70
IDD
Supply Current
Unloaded Outputs
66MHz CLKA (-1, -2, -3, -4)
—
—
32
mA
Select Inputs at VDD or GND 66MHz CLKA (-1H, -2H, -5H)
—
—
50
33MHz CLKA (-1, -2, -3, -4)
—
—
18
33MHz CLKA (-1H, -2H, -5H)
—
—
30
5